14 Kamstrup A/S • 5512887_B2_GB_09.2015
ULTRAFLOW® 54 · DN150-300
4 Clcultor with two flow sensors
MULTICAL® 602/801 cn be used in vrious pplictions with two flow sensors, e.g.
lek surveillnce or open systems. When two ULTRAFLOW® re direct connected to one
MULTICAL® 602/801, close electric coupling between the two pipes ought to be crried out s
min rule. If the two pipes re instlled in het exchnger, close to the flow sensors, however, the
het exchnger will provide the necessry electric coupling.
• Forwrd nd return pipes re closely electriclly coupled
• No welded joints occur
In instlltions where the electric coupling cnnot be crried out, or where welding in the pipe
system cn occur, one ULTRAFLOW® must be mounted with glvniclly seprted output
module nd lso supply of its own.
• Forwrd nd return pipes re not necessrily closely coupled
• Electric welding* cn occur
* Electric welding must lwys be crried out with the erth pole closest to the welding point.
Dmge to meters due to welding is not comprised by Kmstrup’s fctory gurntee.
5 Opertionl check
Crry out n opertionl check when the complete meter (flow sensor nd clcultor) hs been
instlled nd connected. Open thermo regultors nd vlves to estblish wter flow through
the instlltion. Activte the top key of the clcultor nd check tht the displyed vlues for
tempertures nd wter flow re credible vlues.
6 Accessories
Order number Description
5000-333 2.5 m silicone cble (3-wire)
5000-259 5 m silicone cble (3-wire)
5000-270 10 m silicone cble (3-wire)
6561-332 Short distnce piece
Tble 3