Page 15
AUX DISPLAY
P 0.00
→
The AUX (auxillary) display can be
customised via MENU / SCREEN / AUX.
R
0.0008
The parameters displayed on lines 1, 2, 3 and
4 can be set by the user.
Cop 52
They remain the AUX parameters until
changed by the user.
CO
2
%
6.3
Press / to print a full combustion test, (or send to PC via optional
Wireless module).
Hold / for 2+ seconds to log a full combustion report.
VIEWING/PRINTING A LOGGED COMBUSTION REPORT
Select MENU / REPORT / COMB’N / VIEW
Use , and to select the log number to be viewed.
Use and to scroll through the individual readings on lines 2 & 3.
Hold or for 2+ seconds to scroll to the next / previous log number.
Press / to print the test, (or send to PC via optional Wireless module).
NOTE: Before the 100
th
test can be stored the Combustion section of the
memory must be cleared. Make sure you have printed/captured the test
results that you want first. To do this select MENU / REPORT / TIGHTN’S
/ DEL ALL / YES then press Enter. .