Page 33
At the end of a test the display will show
LOG 1
→
This is the first log
TEST 9
→
This test ended after 9 minutes
This is the CO reading at the end of the test
This is the CO2 reading at the end of the
test
COp 40
→
CO2p 800
→
The room air test series is automatically stored in the memory as a log number.
When completed the log can be printed immediately by pressing .
You can also view individual TEST results by pressing the SEND key to scroll through
the individual tests.
Viewing / printing a logged Room Air test
Select MENU / REPORT / ROOM CO / VIEW
Use or to select the log number to be printed.
Use the SEND key to increment the TEST NO being viewed
Press / to print the test, (or send to PC via optional Wireless module).
You can also view individual TEST results by pressing the SEND key to scroll through
the individual tests.
NOTE: During a Room Air test it is not unusual to see CO readings of 2 or 3 ppm
even in a room that is notionally CO free. This can be due to migration, traffic or
smoking.