EasyManua.ls Logo

Kappa Flight Eye FE320 - Maintenance Work; Time Limits; Job Set-Up Information; Table 9-1 Time Limits

Default Icon
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Maintenance Work
Time Limits
No.
Maintenance Activity
Schedule/Interval
1
Replacement of sealing-ring
3000 Flight Hours / 2 Years or in
case that humidity is constantly
discovered on the camera window
(whichever comes first).
The sealing ring must be changed
whenever the camera has been
opened.
Table 9-1 Time Limits
Job Set-up Inform ation
9.2.2.1 Fixtures, Tools, Test and Support Equipm ent
NOTE: Equivalent alternatives of silicone free grease may be used.
No.
Reference
Quantity
Designation
T1
No specific
1
Torque spanner
T2
No specific
1
Wera 840/1 1,5 mm (0.059 in)
T3
No specific
1
Wera 840/1 0,9mm (0.035 in)
T4
No specific
1
Wera 851/1 PH 0
Table 9-2 Fixtures, Tools, Test and Support Equipment
9.2.2.2 Expendables
The following expendables are necessary to do the maintenance tasks:
No.
Reference
Quantity
Designation
E1
434-0331
1
Sealing-ring
(Shelf Life: 5 years)
Table 9-3 Expendables