34 762.885 Z05 2012 coolcept_fleX, coolcept³_fleX
Power factor cosPhi 0.8 capacitive to 0.8 inductive
Highest output fault
current
0.0 A
Highest overcurrent
protection
28 A 40 A
Characterisation of the operating behaviour
Max. efficiency 97.40 % 97.40 % 97.40 % 97.00 % 97.00 %
European efficiency 96.10 % 96.50 % 96.60 % 96.30 % 96.30 %
MPP efficiency > 99.7 % (static), > 99 % (dynamic)
Internal consumption < 20 W
Power derating (power
reduction) at full power
from
50 °C (T
amb
) 45 °C
(T
amb
)
Safety
Isolation principle No galvanic isolation, without transformer
Grid monitoring Yes, integrated
Residual current
monitoring
Yes, integrated (the inverter cannot cause a DC residual
current due to the design)
Protection class Protection class 2 (RCD type A sufficient)
Operating conditions
Area of application Indoors, outdoors (degree of soiling 3)
Climate category i.a.w.
IEC 60721-3-4
4K4H
Ambient temperature -25 °C to +60 °C
Storage temperature -30 °C to +80 °C
Relative humidity 0 % to 100 %, non-condensing
Noise emission
(typical)
31 dB(A)
Degree of protection IP 65
Overvoltage category III (AC), II (DC)
DC connection Phoenix Contact SUNCLIX (1 pair), mating plugs included in
the scope of delivery