EasyManua.ls Logo

KATEK Steca coolcept fleX - 12 Technical Data; Stecagrid 1511, 2011, 2511, 3011 and 3611

KATEK Steca coolcept fleX
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
762.885 Z05 2012 coolcept_fleX, coolcept³_fleX 33
12 Technical data
12.1 StecaGrid 1511, 2011, 2511, 3011 and 3611
Inverter,
1-phase
StecaGrid
1511
StecaGrid
2011
StecaGrid
2511
StecaGrid
3011
StecaGrid
3611
Installation altitude Max. 2000 m above sea level
DC input side (PV generator connection)
Max. input voltage 450 V 750 V
MPP voltage range 75 V to 360 V 125 V to
600 V
150 V to
600 V
Start input voltage 100 V 100 V 100 V 125 V 150 V
Number of MPP
trackers
1
Max. input current 13 A
Max. input power with
max. output active
power
1540 W 2050 W 2560 W 3070 W 3770 W
Max. short-circuit
current
15 A
Maximum inverter
backfeed current to the
PV array
0 A
AC output side (grid connection)
Output voltage 185 V to 276 V
Nominal output voltage 230 V
Max. output current 12 A 12 A 14 A 14 A 16 A
Max. active power
(cosPhi = 1)
1500 W 2000 W 2500 W 3000 W 3680 W
Maximum apparent
power
1500 VA 2000 VA 2500 VA 3000 VA 3680 VA
Nominal power 1500 W 2000 W 2500 W 3000 W 3680 W
Nominal frequency 50 Hz and 60 Hz
Grid frequency 45 Hz to 65 Hz
Power loss during
nighttime operation
< 3 W
Feed-in phases One-phase
Distortion factor
(cosPhi = 1)
< 3 %