762.885 Z05 2012 coolcept_fleX, coolcept³_fleX 39
Inverter, 3-phase
StecaGrid
3213
StecaGrid
4013
StecaGrid
5013
StecaGrid
6013
Operating conditions
Area of application Indoors, outdoors (degree of soiling 3)
Climate category i.a.w.
IEC 60721-3-4
4K4H
Ambient temperature -25 °C to +60 °C
Storage temperature -30 °C to +70 °C
Relative humidity 0 % to 100 %, non-condensing
Noise emission (typical)
29 dB(A)
Equipment and design
Degree of protection IP 65
Overvoltage category III (AC), II (DC)
DC connection Phoenix Contact SUNCLIX (1 pair), mating
plugs included in the scope of delivery
AC connection Wieland RST25i3 plug, mating plug included
in the scope of delivery
Dimensions 399 x 657 x 222 mm
Weight 12.0 kg
Communication interfaces RS-485 (1 x RJ45 socket: connection to
Meteocontrol WEB'log or Solar-Log™),
Ethernet interface (1 x RJ45), Modbus RTU
(1 x RJ45 socket: connection to energy meter)
Integrated DC disconnector Yes, conform to DIN VDE 0100-712
Cooling principle Temperature controlled fan, variable-speed,
internal (dust-protected)
Test certificate Refer to certificates download at the product
page of homepage