6 1
Name: Basis
KEB COMBIVERT F5-G / B
24
24.06.02
Functional Description
© KEB Antriebstechnik, 2002
All rights reserved
Chapter Section Page Date
Operating and Appliance Data
Adr.
min max
default
0035h
1
rpm
0
16000-16000
Sy. 53 Actual speed value
With this parameter the current actual speed can be readout in rpm. The direction of rotation is signaled by the sign.
Adr.
min max
default
0038h
1
hex
0203
7FFF0
Sy. 56 Start display address
Sy.56 adjusts the parameter address which shall be represented on switching on the operator. Only valid addresses are
accepted.
If this parameters is available in the CP-Mode, the setting becomes effective there. Otherwise CP.0 is indicated as start
parameter.