6
47
KEB COMBIVERT F5-G / B
Name: Basis
06.02.02
6
© KEB Antriebstechnik, 2002
All rights reserved
Functional DescriptionSet Value and Ramp Adjustment
Section PageDate Chapter
Rotation adjustment via terminal
strip
oP.1 = „2“ or „3“
FR
F/RRun/Stop
Input selection
Rotation direction F (Run/Stop) oP.60
Rotation direction R (forward/
reverse) oP.61
The rotation selection via terminal strip allows the adjustment of the direction of
rotation via switch or from a primary control.
With parameter oP.60 one input is determined for rotation direction forward (or run/
stop) and with oP.61 one input for rotation direction reverse (or forward/reverse).
Bit -No. Decimal value Input Terminal
0 1 ST (Prog. input „Control release/Reset“) X2A.16
1 2 RST (Prog. input „Reset“) X2A.17
2 4 F (Prog. input „Forward“)
1)
X2A.14
3 8 R (Prog. input „Reverse“)
2)
X2A.15
4 16 I1 (Prog. input 1) X2A.10
5 32 I2 (Prog. input 2) X2A.11
6 64 I3 (Prog. input 3) X2A.12
7 128 I4 (Prog. input 4) X2A.13
8 256 IA (Internal input A) none
9 512 IB (Internal input B) none
10 1024 IC (Internal input C) none
11 2048 ID (Internal input D) none
1) default at oP.60 2) default at oP.61
In the case of rotation selection forward/reverse (oP.1= „2“ or „3“) the inputs determined
with oP.60 and oP.61 work as follows:
Forward Revers Input
F R Function
00LS
0 1 Reverse
1 0 Forward
1 1 Forward
In the case of rotation selection run/stop and forward/reverse (oP.1= „4“ or „5“) the
inputs determined with oP.60 and oP.61 work as follows:
Revers Forward Input
F/R Run/Stop Function
00LS
0 1 Forward
10LS
1 1 Reverse
oP.1 = „4“ or „5“
X2A.14 X2A.15
X2A.14 X2A.15