46
Generalcontrolcardparameters(operatorfunctionality)
Parameter Id-Text Name CANSDOIndex
os04 Diag error count 0x2084
Subindex 0
Object type Variable
Data length unsigned Byte
Access Read write
Meaning Speciesthenumberofoccurrederrorsonthediagnosticinterface.
Coding 0…255
Parameter Id-Text Name CANSDOIndex
os05 Diag response delay time 0x2085
Subindex 0
Object type Variable
Data length unsigned Byte
Access Read write
Meaning Adjusts the minimum response delay time for inquiries over the diag-
nostic interface.
Coding 0…126 ms
Parameter Id-Text Name CANSDOIndex
os06 Diag baud rate 0x2086
Subindex 0
Object type Variable
Data length unsigned Byte
Access Read write
Meaning Setting the transmission speed on the diagnostic interface.
Coding
0 1.2 Kbit/s
5 38.4 Kbit/s
1 2.4 Kbit/s
6 55.5 Kbit/s
2 4.8 Kbit/s
7 57.6 Kbit/s
3 9.6 Kbit/s
8 100 kbit/s
4 19.2 Kbit/s
Standard 5
Parameter Id-Text Name CANSDOIndex
os07 node ID 0x2087
Subindex 0
Object type Variable
Data length unsigned Byte
Access Read write
Meaning Thisparameterspeciestheinverteraddressforthediagnosticinter-
face (DIN 66019). The parameter is a mapping of the system param-
eter Sy06. If the inverter address is changed via bus, then there is no
longer access.
Coding 0…239