Generalcontrolcardparameters(operatorfunctionality)
Parameter Id-Text Name CANSDOIndex
os08 operator type 0x2088
Subindex 0
Object type Variable
Data length unsigned Word
Access Read only
Meaning Display of the functions implemented in the control card.
Coding
Bit 0
Initiator 0:without
1:withinitiator
Bit 1
Keyboard/dis-
play
0:without
1:withkeyboard/LCDdisplay
Bit 8
LT image 0:withpowerunitimage
1:withoutpowerunitimage
Bit 10
f=0Hz 0:without
1:withf=0Hzfunctionality
Bit 11
STO 0:withoutsafetyfunction
1:withsafetyfunctionSTO
Bit 12…13
Bus connec-
tion
0:without(standard)
1:CANopen
2:IO-link
3:EtherCAT
4:VARAN
Standard Device dependent
Parameter Id-Text Name CANSDOIndex
os09 PUmaxinvbusyretries 0x2089
Subindex 0
Object type Variable
Data length unsigned Byte
Access Read write
Meaning Number of retries which are sent on the internal bus from the power
unit to the control if this rejects the service with the error "inverter
busy".
Coding 0…255
Standard 200
Parameter Id-Text Name CANSDOIndex
os10 PU tout count 0x208A
Subindex 0
Object type Variable
Data length unsigned Word
Access Read write
Meaning Counts the timeouts on the internal bus between the control and pow-
er unit.
Coding 0…255
Standard 200

Other manuals for KEB COMBIVERT G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT G6 and is the answer not in the manual?

KEB COMBIVERT G6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT G6
CategoryDC Drives
LanguageEnglish

Related product manuals