Handheld Terminal Accessories
User's Manual, version: 3.1 / material no.: 57448 113
© KEBA 2006
KeTop CB211 Connection Box
The KeTop CB211 connection box is used for integration of the KeTop in the
machine/system. It is suitable for wall mounting and can also be mounted on a
mounting rail through the use of the mounting rail assembly kit (KeTop
DR200). The KeTop CB211 connection box has the following connections:
Construction
70
165
140
1
2
3
4
5
6
1.......Status and error LEDs
2.......PG gland (M20) for voltage supply, enabling switch and emergency stop
3.......PG gland (M16) for separate functional ground (status as supplied with dummy plugs)
4.......Coninvers female connector for KeTop T100, T50 and T40 - connection cable
5.......PG glands (M16)for data lines
6.......PG glands (M16) for data lines (status as supplied with dummy plugs)
View and device description of the Gateway box
WARNING
!
The connection box and the handheld terminal meet the safety class III in accor-
dance with EN61131-2 and EN50178.
When connecting the handheld terminal, make sure that all voltages connected
to the handheld terminal are safety extra low voltages and isolated from the low
voltage supply system by a safety transformer or a similar facility.