Handheld Terminal Software
User's Manual, version: 3.1 / material no.: 57448 53
© KEBA 2006
KtpSetScreenSaverTimeOutSec
Declaration
UINT8 SetScreenSaverTimeOut-
Min(/*[in]*/UINT16u16_ScreenSaverTO);
Description
Sets the timeout value of the screensaver in seconds.
Arguments
0-65535, 0 = off, 65535 = max
KtpSetBuzzerVolume
Declaration
UINT8 KtpSetBuzzerVolume(/*[in]*/UINT8 u8_Volume);
Description
Sets the volume of the buzzer.
Arguments
0-16, 0 = off, 16 = max