Flexlite GX
Operating manual - EN
6.4 Technical data: Flexlite GX 400A (gas-cooled)
Flexlite GX 403G / 405G 408GMN
Feature Value
Welding process
MIG/MAG MIG/MAG
Contact tip
M10x1 M10x1
Method of guidance
Manual Manual
Type of cooling
Air Air
Coolant max. pressure (bar)
- -
Min. cooling power at 1l/min * (kW)
- -
Min. flow rate (l/min)
- -
Type of connection
Euro Kemppi
Wire diameters (mm)
0.8...1.6 0.8...1.6
Load capacity:
35% / Ar + 18% CO₂
400 A -
60% / Ar + 18% CO₂
- 400 A
100% / Ar + 18% CO₂
- -
35% / CO₂
- -
60% / CO₂
- -
100% / CO₂
- -
Gas flow (l/min) in load capacity test
20 20
Filler wire diameter in load capacity test
1.6 1.6
Stick out length in load capacity test
22 22
Filler wire diameters (mm):
Fe
0.8...1.6 0.8...1.6
Fe-MC/FC
0.9...1.6 0.9...1.6
Ss
0.8...1.6 0.8...1.6
Ss-MC/FC
0.9...1.6 0.9...1.6
Al
0.8...1.6 0.8...1.6
Operating temperature range
-20°C…+40°C -20°C…+40°C
Storage temperature range
-40°C…+60°C -40°C…+60°C
Pistol grip handle
Yes Yes
Rotating neck
Yes Yes
Changeable neck
No Yes
Neck dimensions:
Length x (mm) ( see figure below )
156 132
Height y (mm) ( see figure below )
112 110
Neck angle ɑ (°) ( see figure below )
50 50
© Kemppi
48
1921390 / 2310