Flexlite GX
Operating manual - EN
6.7 Technical data: Flexlite GX 600A (water-cooled)
Flexlite GX 605W 608W
Feature Value
Welding process
MIG/MAG MIG/MAG
Contact tip
M10x1 M10x1
Method of guidance
Manual Manual
Type of cooling
Liquid Liquid
Coolant max. pressure (bar)
5 5
Min. cooling power at 1l/min * (kW)
0.9 -
Min. cooling power at 1.6l/min * (kW)
- 1.9
Min. flow rate (l/min)
1 1.6
Type of connection
Euro Kemppi
Wire diameters (mm)
1.2...2.4 1.2...2.4
Load capacity:
35% / Ar + 18% CO₂
600 A (40%) 600 A (40%)
60% / Ar + 18% CO₂
- -
100% / Ar + 18% CO₂
- -
35% / CO₂
- -
60% / CO₂
- -
100% / CO₂
- -
Gas flow (l/min) in load capacity test
25 25
Filler wire diameter in load capacity test
1.6 1.6
Stick out length in load capacity test
25 25
Filler wire diameters (mm):
Fe
1.2...2.4 1.2...2.4
Fe-MC/FC
1.2...2.4 1.2...2.4
Ss
1.2...1.6 1.2...1.6
Ss-MC/FC
1.2...1.6 1.2...1.6
Al
1.2...2.4 1.2...2.4
Operating temperature range
-20°C…+40°C -20°C…+40°C
Storage temperature range
-40°C…+60°C -40°C…+60°C
Pistol grip handle
Yes Yes
Rotating neck
No No
Changeable neck
No No
Neck dimensions:
Length x (mm) ( see figure below )
255 251
Height y (mm) ( see figure below )
74 72
© Kemppi
54