EN
4.3.2 Welding functions
OTHER PROCESSES
(In Edit Channel menu 3/6)
HotStart
ON, OFF or USER Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF
HOTStartLevel
-50 – 100 % 1 % steps. Factory setting 40 %
Hot 2T Time
0 – 9.9 s 0.1 s steps. Factory setting 1.2 s
CraterFill
ON, OFF, USER Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF
CraterStart
10 – 250% Factory setting is 100% Set the level of the curve where the crater
lling will start
CraterFillEnd
10 – 250 %, not
higher than start
1 % steps. Factory setting 30% Set the level of the curve where the crater
lling will end.
CraterTime
0.0 – 10.0 s 0.1 s steps. Factory setting 1.0 s CrateFill Slope Time
Creep Start
10 – 99% 1% steps. OFF, CURVE
(OFF = 100%)
Factory setting is CURVE (Creep Start value
comes from Welding Curve).
StartPower
-9 – 9 Factory setting is 0 Adjusts arc ignition
WISEROOT / WISETHIN
HotStart
ON, OFF or USER Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF
HOTStartLevel
-50 – 100 % 1 % steps. Factory setting 40 %
Hot 2T Time
0 – 9.9 s 0.1 s steps. Factory setting
1.2 s
CraterFill
ON, OFF, USER Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF
CraterStart
10 – 250% Factory setting is 100% Set the level of the curve where the crater
lling will start.
CraterFillEnd
10 – 250 %, not
higher than start
1 % steps. Factory setting 30%
CraterTime
0.0 – 10.0 s 0.1 s steps. Factory setting
1. 0 s
Creep Start
10 – 99% 1% steps. OFF, CURVE
(OFF = 100%)
Factory setting is CURVE (Creep Start value
comes from Welding Curve).
ADVANCED FUNCTIONS
WisePenetration
ON or OFF Penetration control selection
Penet%(123A)
-30 – 30 % Factory setting: 0 % Wise penetration percent setting. Set
penetration Current.
WiseFusion
ON or OFF WiseFusion selection
WiseFusion%
20 - 60 % or CURVE Factory setting is CURVE When WISE FUSION is ON it controls the
amount of short circuits in the arc. The
lower the value there will be less short
circuits in the arc. The higher the value
there will be more short circuits in the arc.
MatchLogLevel
-50 – 100% Set the “MiniLog level”
Only in use in case of manual feeder.
14
KempArc Pulse 350, 450 / © Kemppi Oy / 1044

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi KempArc Pulse 350 and is the answer not in the manual?

Kemppi KempArc Pulse 350 Specifications

General IconGeneral
BrandKemppi
ModelKempArc Pulse 350
CategoryWelding System
LanguageEnglish

Related product manuals