4.3 WELDING PARAMETRES AND FUNCTIONS
4.3.1 Welding parametres (In Edit Channel menu 2/6)
MIG
WFSpeed
0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
Voltage
8 – 50V 0.1V steps Controls the length of the arc
Dynamics
-9 – 9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
1-MIG
WFSpeed
0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
Factory setting is 0
( = curve point)
Adjusts the arc voltage of the curve within certain
limits. In other words, it adjusts the length of the arc
within certain limits
FineTuningMax
0 – 9 0.5 steps Set the limit for maximum arc length
FineTuningMin
-9 – 0 0.5 steps Set the limit for minimum arc length
Dynamics
-9 – 9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
PULSE MIG
WFSpeed
0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
Factory setting is 0
( = curve point)
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
FineTuningMax
0 – 9 0.5 steps Set the limit for maximum arc length
FineTuningMin
-9 – 0 0.5 steps Set the limit for minimum arc length
Dynamics
-9 – 9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10% – 15% Factory Setting
is 0%
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%.
12
KempArc Pulse 350, 450 / © Kemppi Oy / 1044