Master M 205, 323
Operating manual - EN
Crater fill
ON/OFF
Default = OFF
When welding with high power, a crater
is usually formed at the end of the weld.
The Crater fill function decreases the
welding power / wire feed speed at the
end of the welding job so that the crater
can be filled using a lower power level.
Crater fill duration, wire feed speed and
voltage are preset by the user. The crater
fill start level cannot be smaller than the
crater fill end level.
When the 4T timer is set to ON, releasing
the trigger during crater fill does not end
welding.
- Crater fill start level
10 ... 150 %, step 1
Default = 100 %
- Crater filltime
0.1 ... 10.0 s, step 0.1
Default = 1.0 s
- Crater fillend level
10 ... 150 %, step 1
Default = 10 %
- Crater fill 4T timer
ON/OFF
Pulse welding parameters (Master M 205 only)
The parameters listed here are available for adjustment with the pulse welding process in addition to the MIG and 1-MIG weld-
ing parameters. For more information on the processes, refer to "Additional guidance to functions and features" on page47.
Parameter Parameter value Description
Pulse current %
-10 … 15 %
Default = 0 %
The pulse current relative to the base cur-
rent in pulse welding.
3.3.7 Control panel: System settings
Changing settings
1. Turn the right control knob to highlight the desired settings parameter.
2. Press the right control knob to select the settings parameter for adjustment.
3. Turn the right control knob to select the settings value.
>> Depending on the settings parameter to be adjusted, refer also to the Settings table below for more details.
4. Confirm the new value / selection by pressing the right control knob.
Settings
Parameter Parameter value Description
Remote
ON/OFF Select whether remote is used.
Remote selection
Gun remote If Remote is ON, then GXR10 gun remote
control is used for controlling the wire
feed speed or memory channels.
© Kemppi
44
1922130 / 2313