Master M 205, 323
Operating manual - EN
Cable calibration
(MIG only)
Start/Cancel Calibration information on the previous
calibration is also shown. Refer to "Cal-
ibrating welding cable" on page35 for
cable calibration.
Water cooler
OFF/Auto/ON
Default = Auto
When ON is selected, the coolant is cir-
culated continually, and when Auto is
selected, the coolant is circulated only
during welding.
Cycle timer
ON/OFF
Default = OFF
A welding function that automatically
produces a weld of a predefined dur-
ation.
- Cycle timer time
0.0 ... 60.0 s
Default = 2.0 s
WF end step
OFF/ON
Default = OFF
Wire feed end step feature prevents the
filler wire from sticking to the contact tip
when the welding ends.
Weld data duration
0...10 s, step 1
Default = 5 s
This defines how long the weld data sum-
mary is shown after each weld.
Safe wire inch
(MIG only)
OFF/ON
Default = ON
When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm. When OFF, 5 m of
filler wire is fed.
Gas guard (Master M 323 only)
ON/OFF
Default = OFF
Gas guard prevents welding without
shielding gas.
Voltage display
Arc voltage / Terminal voltage
Default = Arc voltage
This defines which is shown on the con-
trol panel display, arc or terminal voltage.
Wire inch
0.5 ... 18.0 m/min
Default = 5.0 m/min
Drive the filler wire forward (with arc off).
Gas test
0 60 s
Default = 20 s
Test the shielding gas flow and flush the
gas line.
Language
Available languages
PIN code
ON/OFF 4-digit PIN code for locking the control
panel after 30 s of inactivity. PIN lock does
not prevent welding, browsing Powerlog
levels or selecting memory channel.
Device info
Shows information on the device and its
usage.
Factory reset
Reset/Cancel
Default = Cancel
Restores factory settings. Note that the
arc verification parameter value is also
reset.
3.3.8 Control panel: Weld data
After each weld, a weld summary is displayed briefly. To change the weld data view duration, refer to "Control panel: Sys-
tem settings" on the previous page.
© Kemppi
45
1922130 / 2313

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi Master M 205 and is the answer not in the manual?

Kemppi Master M 205 Specifications

General IconGeneral
BrandKemppi
ModelMaster M 205
CategoryWelding System
LanguageEnglish

Related product manuals