5. Open the gas bottle valve.
6. Press the gas test button (1) to test and adjust the gas flow. Use the gas regulating valve (2) (in Master M 355 only)
or an external flow meterand regulator.
The gas test time is 20 seconds by default. The gas test time can be changed in the control panel.
Recommended gas flow rates (for general guidance only):
TIG* MIG**
Argon
5...15 l/min 10...25 l/min
Helium
15...30 l/min -
Argon + 18-25% CO2
- 10...25 l/min
CO2
- 10...25 l/min
* Depending on the gas nozzle size.
** Depending on the gas nozzle size and welding current.