Master M 353, 355
Operating manual - EN
5.2 Master M cooling unit
Master M Cooler
Master M Cooler
Feature Value
Supply voltage
U
1
380...460 V +/- 10 %
Maximum supply current @ 380...460 V
I
1max
0.7 A
Cooling power @ 1 l/min
1.0 kW
Recommended coolant
MGP 4456 (Kemppi mixture)
Maximum coolant pressure
0.4 MPa
Tank volume
3 l
Operating temperature
range
With recommended coolant
-20...+40 °C
Storage temperature range
-40...+60 °C
EMC class
A
Degree of protection When mounted
IP23S
Package external dimensions
L
x
W
x
H
635 x 305 x 292 mm
Weight Without accessories
14.9 kg
Standards
IEC 60974-2, -10
Master M Cooler MV
Master M Cooler MV
Feature Value
Supply voltage
U
1
220...240 V +/- 10 %
380...460 V +/- 10 %
Maximum supply current @ 220...230 V
I
1max
1.0 A
@ 380...460 V
I
1max
0.7 A
Cooling power @ 1 l/min
1.0 kW
Recommended coolant
MGP 4456 (Kemppi mixture)
Maximum coolant pressure
0.4 MPa
Tank volume
3 l
Operating temperature
range
With recommended coolant
-20...+40 °C
Storage temperature range
-40...+60 °C
EMC class
A
Degree of protection When mounted
IP23S
Package external dimensions
L
x
W
x
H
635 x 305 x 292 mm
Weight Without accessories
14.9 kg
Standards
IEC 60974-2, -10
© Kemppi