>> This adjustment is not available when the Lift TIG ignition is turned on.
Upslope: Min/Max = 0.0 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
Hot start level: Min/Max = -80% ... +100%, 1% step (Default = Off), Value '0' = Hot start off
Hot start time: Min/Max = 0.1 s ... 9.9 s, 0.1 s step (Default = 1.2 s)
>> This adjustment is not available when Hot start is off.
>> Hot start time cannot be adjusted when 4T trigger logic is selected.
Minilog: Min/Max = -99% ... +125%, 1% step (Default = Off), Value '0' = Minilog off
>> This adjustment is not available when the 2T trigger logic is selected.
Downslope: Min/Max = 0.0 s ... 15.0 s, 0.1 s step (Default = 0.1 s)
Post gas: Min/Max = 0.0 s ... 30.0 s, Auto, 0.1 s step (Default = Auto)
Adjustable parameters in spot welding:
Pre gas: Min/Max = 0.0 s ... 9.9 s, Auto, 0.1 s step (Default = Auto)
>> This adjustment is not available when the Lift TIG ignition is turned on.
Upslope: Min/Max = 0.0 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
Downslope: Min/Max = 0.0 s ... 15.0 s, 0.1 s step (Default = 0.1 s)
Post gas: Min/Max = 0.0 s ... 30.0 s, Auto, 0.1 s step (Default = Auto)
Adjustable parameters in MicroTack welding:
Pre gas: Min/Max = 0.0 s ... 9.9 s, Auto, 0.1 s step (Default = Auto)
>> This adjustment is not available when the Lift TIG ignition is turned on.
Post gas: Min/Max = 0.0 s ... 30.0 s, Auto, 0.1 s step (Default = Auto)
Adjustable parameters in AC mode:
Balance: -60 % ... 0 % (Default = -25%)
AC Frequency: 30 Hz ... 250 Hz (Default = 60 Hz)
Adjustable parameters in Pulse mode:
Pulse current: 2 A ... Power source max A, 1 A step *
Pulse ratio: 10 % ... 70 %, 1 % step (Default = 40 %) *
Base current: 10 % ... 70 %, 1 % step (Default = 20 %), amperes visible *
Pulse frequency (DC): 0.2 Hz ... 300 Hz, 1 Hz step (0.2 Hz ... 10 Hz step is 0.1 Hz) (Default = 1 Hz) *
Pulse frequency (AC): 0.2 Hz ... 20 Hz, 1 Hz step (0.2 Hz ... 10 Hz step is 0.1 Hz) (Default = 1 Hz) *
* Auto Pulse mode has different parameter values and they cannot be adjusted.