TROUBLESHOOTING
ALL BRUSHES DO NOT ROTATE
Possible causes
The brush enabling microswitch is misadjusted or broken (adjust or replace).1.
The wiring harness between microswitch and function electronic board is damaged (repair).2.
The brush motor electromagnetic switch wiring harness is damaged (repair).3.
The function electronic board is damaged (replace).4.
The wiring harness between function electronic board and brush motor electromagnetic switch is damaged (repair).5.
The brush motor electromagnetic switch is damaged (replace).6.
The brush motor fuse is open (replace).7.