Page #46 background imageLoading...
Page #46 background image
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
3-3 Cyclic communication
3-16
3
Communicating with the GT2 Series
Parameter List
Name Function Operation
External
Input
Request 1
Preset
ON: Executes preset. Executing preset turns on external input
response 1.
OFF: Turns off external input response 1.
External
Input
Request 2
Timing
execution
ON: Turns on timing. Turning on timing also turns on external input
response 2.
OFF: Turns off timing. Turning off timing also turns off external input
response 2.
External
Input
Request 3
Reset Request
ON: Executes reset. Executing reset turns on external input
response 3.
OFF: Turns off external input response 3.
External
Input
Request 4
Error clear
ON: Executes error clear. Executing error clear turns on external
input response 4.
OFF: Turns off external input response 4.
External
Input
Request 5
(Unassigned) (Unassigned)