- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
3-4 Message Communication
3-42
3
Communicating with the GT2 Series
Group4
038EH
(910)
Display
resolution
Indicates the display resolution.
Parameter range: 0 to 3 (initial value: 0)
0: 0.0001
1: 0.001
2: 0.01
3: ___0.1
R/W DINT
038FH
(911)
Hysteresis
Indicates the hysteresis.
Parameter range: 0.0000 to 199.9999
(Initial value: 0.0030)
R/W DINT
0390H
(912)
Simultaneous
input
setting
*12
Indicates the simultaneous input setting.
Parameter range: 0 to 1 (initial value: 0)
0: Individual input
1: Simultaneous input
R/W DINT
0391H
(913)
Special output
setting
*
1,
*
14
Indicates the special output setting.
Parameter range: 0 to 5 (initial value: 0)
0: Not used
1: 5-output
2: Limit output
3: Limit output user setting
4: All GO
5: All limit output
R/W DINT
0392H
(914)
Limit output
HH position
*1
Indicates the limit output HH position.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.5000)
R/W DINT
0393H
(915)
Limit output
LL position
*1
Indicates the limit output LL position.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.5000)
R/W DINT
0394H
(916)
Select preset
data
Indicates the select preset data.
Parameter range: 0 to 1 (initial value: 0)
0: R.V. value
1 : P. V. v al ue
R/W DINT
0395H
(917)
Preset
memory
Indicates the preset memory.
Parameter range: 0 to 1 (initial value: 0)
0: YES
1: NO
R/W DINT
0396H
(918)
Preset point
Indicates the preset point.
Parameter range: 0 to 1 (initial value: 0)
0: Common to all banks
1: Save for each bank
R/W DINT
0397H
(919)
Power-saving
function
(ECO)
Indicates the power-saving function (ECO).
Parameter range: 0 to 2 (initial value: 0)
0: OFF
1: HALF
2: ALL
R/W DINT
0398H
(920)
Jam
detection
function
Indicates the jam detection function.
Parameter range: 0 to 2 (initial value: 0)
0: OFF
1: ON
2: USER
R/W DINT
0399H
(921)
Jam
detection
position
Indicates the jam detection position.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.5000)
R/W DINT
Class
Attribute
ID
Name Description
Attribute
Data
Ty p e

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keyence DL-EP1 and is the answer not in the manual?

Keyence DL-EP1 Specifications

General IconGeneral
BrandKeyence
ModelDL-EP1
CategoryControl Unit
LanguageEnglish