- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
3-4 Message Communication
3-44
3
Communicating with the GT2 Series
*1 When GT2-71MC* is used, these cannot be read and written.
*2 Use these in combination with the comparator value property (Current Value n
Over Range, Current Value n Under Range, Current Value n Invalid).
*3 If the calculation function is used and the calculation setting is other than
standard difference display, a read error occurs in the expansion unit.
*4 If this value is Current Value Over Range, 999.9999 is stored.
If this value is Current Value Under Range, -999.9999 is stored.
If this value is Current Value Invalid, -999.9998 is stored.
If this value is Error, 1000.0000 is stored.
*5 For calculation-only mode, a read error occurs in the main unit.
Group6
03C0H
(960)
Group6
Entry count
Indicates the number of items (entries) that can
be set in Group 6.
Parameter range: 11
RDINT
03C1H
(961)
Product code
Indicates the product code.
Parameter range:
GT2-7*(main unit) : 4006
GT2-7*(expansion unit) : 4007
GT2-71MC* : 4008
GT2-100*(main unit) : 4010
GT2-100*(expansion unit) : 4011
RDINT
03C2H
(962)
Revision
Indicates the revision.
Parameter range: 0101H to FFFFH
RDINT
03C3H
(963) to
03C7H
(967)
Reserved for system
03C8H
(968)
Product
name
Indicates the product name.
Parameter range:
GT2-7*(main unit) : "GT2-71*/75*"
GT2-7*(expansion unit) : "GT2-72*/76*"
GT2-71MC* : "GT2-71MC*"
GT2-100*(main unit) : "GT2-100*"
GT2-100*(expansion unit) : "GT2-100*"
R
STRING
03C9H
(969) to
03D6H
(982)
Reserved for system
03D7H
(983)
Series code
Indicates the series code.
Parameter range:
GT2-7*(main unit) : 4006
GT2-7*(expansion unit) : 4007
GT2-71MC* : 4008
GT2-100*(main unit) : 4010
GT2-100*(expansion unit) : 4011
RDINT
03D8H
(984)
Series version
Indicates the series version.
Parameter range: 1
RDINT
03D9H
(985)
Device type
Indicates the device type.
Parameter range: 0
RDINT
03DAH
(986) to
03DFH
(991)
Reserved for system
Class
Attribute
ID
Name Description
Attribute
Data
Ty p e