SA (Spectrum Analyzer) Mode (Option 233–Mixed Analyzers)
SA Mode Settings
When the table edits are complete
—Press Done
to close the Antenna/Cable Editor.
—Press Save Antenna
or Save Cable to save your changes to the specified
Storage Device. Enter a filename using the FieldFox labeler (learn more in
“How to use the FieldFox labeler ” on page 724). Learn more about
Antenna and Cable files below.
—Press Recall Antenna
or Recall Cable to load an Antenna or Cable file from
the specified Storage Device.
Storage Device
Changes the device used to save or recall files. Choose
from Internal (default setting), USB (must be connected) or SD card. This is
a different setting from the Save/Recall Storage Device setting.
About Antenna and Cable files
Cable files are saved and recalled from the Cables folder.
Antenna files are saved and recalled from the Antenna folder.
—To DELETE Cable or Antenna files, use the Manage Files feature. Learn more
in “Manage Files” on page 730.
If the folder does not already exist on a USB or SD card, it is created
automatically before storing the file.
All SA mode Antenna and Cable files are saved and recalled as *.csv files,
which allows them to also be read by spreadsheet programs.
The FieldFox can also read *.ANT (Antenna) files that were created from
older Keysight Spectrum Analyzers.
SA Mode cable or antenna (*.csv or *.ANT) files can NOT be edited in Data
Link software.
How to create a Cable file from an S21 (NA mode) or an Insertion Loss
(CAT mode) measurement
1. Measure the S21 or Insertion Loss of a cable. In NA mode, select either
LogMag, Linear, or VSWR formats.
2. Use Manage Folders to change the active folder to CABLES. Learn how in
“Manage Files” on page 730.
3. While in NA mode, save the measurement as a *.csv file. Learn how in
“How
to Save a File” on page 722.
4. In SA mode, select Corrections, then recall the *.csv file for correction.
Source Tracking Offset and Offset Reversal
This feature requires: