Characteristics and Specifications 7
Environmental Characteristics
E3632A User’s Guide 169
Environmental Characteristics
Refer to “Environmental Conditions” on page VI
Electrical Specifications
Table 7 - 2 Electrical specifications
Voltage output (V)
(at 0 C to 40 C)
Low range 0 V to 15 V
High range 0 V to 30 V
Current output (A)
(at 0 C to 40 C)
Low range 0 A to 7 A
High range 0 A to 4 A
Programming accuracy
[1]
12 months (at 25 C 5 C,
% of output offset)
Voltage 0.05% 10 mV
Current 0.2% 10 mA
Readback accuracy
[1]
12 months (over GPIB and RS-232
or front panel with respect to the
actual output at 25 C 5 C), %
of output offset)
Voltage 0.05% + 5 mV
Current 0.15% + 5 mA
Ripple and noise
(with outputs ungrounded, or with
either output terminal grounded,
20 Hz to 20 MHz)
Normal mode
voltage
0.35 mVrms and 2 mVpp
Normal mode
current
2 mArms
Common mode
current
1.5 Arms
Load regulation
(% of output offset)
(Change in output voltage or
current for any load change within
ratings with remote sensing
connected)
Voltage 0.01% 2 mV
Current 0.01% 250 A

Table of Contents

Other manuals for Keysight E3632A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight E3632A and is the answer not in the manual?

Keysight E3632A Specifications

General IconGeneral
BrandKeysight
ModelE3632A
CategoryPower Supply
LanguageEnglish

Related product manuals