EasyManua.ls Logo

Keysight E3632A - Electrical Specifications

Keysight E3632A
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Characteristics and Specifications 7
Environmental Characteristics
E3632A User’s Guide 169
Environmental Characteristics
Refer to “Environmental Conditions” on page VI
Electrical Specifications
Table 7 - 2 Electrical specifications
Voltage output (V)
(at 0 C to 40 C)
Low range 0 V to 15 V
High range 0 V to 30 V
Current output (A)
(at 0 C to 40 C)
Low range 0 A to 7 A
High range 0 A to 4 A
Programming accuracy
[1]
12 months (at 25 C 5 C,
% of output offset)
Voltage 0.05% 10 mV
Current 0.2% 10 mA
Readback accuracy
[1]
12 months (over GPIB and RS-232
or front panel with respect to the
actual output at 25 C 5 C), %
of output offset)
Voltage 0.05% + 5 mV
Current 0.15% + 5 mA
Ripple and noise
(with outputs ungrounded, or with
either output terminal grounded,
20 Hz to 20 MHz)
Normal mode
voltage
0.35 mVrms and 2 mVpp
Normal mode
current
2 mArms
Common mode
current
1.5 Arms
Load regulation
(% of output offset)
(Change in output voltage or
current for any load change within
ratings with remote sensing
connected)
Voltage 0.01% 2 mV
Current 0.01% 250 A

Table of Contents

Other manuals for Keysight E3632A

Related product manuals