101
Command Reference
DANalyse Subsystem
Y Scale Reference Position
DANalyse:ASK|FSK:VIEW:Y:RPOSition TOP|CENTer|BOTTom
DANalyse:ASK|FSK:VIEW:Y:RPOSition?
Sets the reference position of the Y scale.
Key access:
> ASK/FSK Modulation Analysis > Y Scale > Ref Position
Y Scale Auto
DANalyse:ASK|FSK:VIEW:Y:AUTO
Triggers a sweep and sets the Y scale according to the test result
automatically.
Key access:
> ASK/FSK Modulation Analysis > Y Scale > Auto Scale
External Gain
DANalyse:ASK|FSK:VIEW:Y:EXTGain <value>
DANalyse:ASK|FSK:VIEW:Y:EXTGain?
Sets the External Gain for the carrier power measurement.
Key access:
> ASK/FSK Modulation Analysis > Y Scale > Ext Gain