Command Reference
CALCulate Subsystem
70
CALCulate:MARKer Subsection
Markers All Off on All Traces
:CALCulate:MARKer:AOFF
Turns off all markers on all the traces.
Key access:
> All Off
Continuous Peaking Marker Function
:CALCulate:MARKer[n]:CPEak[:STATe] OFF|ON|0|1
:CALCulate:MARKer[n]:CPEak[:STATe]?
Turns on or off continuous peaking. It continuously puts the
selected marker on the highest displayed signal peak.
*RST: Off
Remarks: This command may not be used to activate a given marker.
Key access: > More > Continuous Pk On Off
Frequency Counter Marker Resolution
:CALCulate:MARKer:FCOunt:RESolution <real>
:CALCulate:MARKer:FCOunt:RESolution?
Sets the resolution of the marker frequency counter. Setting the
resolution to AUTO will couple the marker counter resolution to the
frequency span.
*RST: 1 kHz
Range: 0.1 Hz to 1 kHz
Default Unit: Hz
Key access:
> Function > Freq Counter > Resolution Auto Man
Marker
NOTE
This function is intended to maintain the marker on signals with a
frequency that is changing, and an amplitude that is not changing.
Peak
Search
Marker