45
d5.10
30000210
Voltage_360
ADC original data when DC bus voltage is 360 V
Note:Factory parameters
N/A
d5.11
60F60610
Comm_Shift_UVW
Indicates the excitation pointer of a motor
Note:Factory parameters
N/A
d5.12
26000010
Error_Mask
Indicates error masks
Note:Factory parameters
FFF.F
d5.13
60F70510
RELAY_Time
Indicates the relay operating time of capacitor
short-circuits
Unit: mS
Note:Factory parameters
150
d5.14
2FF00408
Key_Address_F001
Sets numeric display data
N/A
d5.15
65100B10
RS232_Loop_Enable
01 to 1. 11 to N
N/A
d5.16
2FFD0010
User_Secret
User password.16bits.
0
65535