44
"E1".............................314.5………….........SME60S-0040-30
"E2"..............................324.5………………..SME80S-0075-30
d4.19
64101410
Motor_Num
The same function as d4.01.But it is specially used for
configuring motor at the first time,and neednt restart driver.
Parameter List: Group F005 (To Set Driver Parameters)
Numeric
Display
Internal
Address
Variable Name
Meaning
Default
Value
d5.00
2FF00108
Store_Loop_Data
1: Stores all control parameters except motor
parameters
10: Initializes all control parameters except motor
parameters
0
d5.01
100B0008
ID_Com
Station No. of Drivers
Note: To change this parameter, you need to save it
with the address “d5.00”, and restart driver later.
1
d5.02
2FE00010
RS232_Bandrate
Sets the baud rate of a serial port
540 19200
270 38400
90 115200
Note: To change this parameter, you need to save it
with the address “d5.00”, and restart driver later.
270
d5.03
2FE10010
U2BRG
Sets the baud rate of the serial port
540 19200
270 38400
90 115200
You need not restart driver.
270
d5.04
60F70110
Chop_Resistor
Indicates the values of braking resistors
0
d5.05
60F70210
Chop_Power_Rated
Indicates the nominal power of a braking resistor
0
d5.06
60F70310
Chop_Filter
Indicates the time constant of a braking resistor
Time: N*256/1000 Unit: S
60
d5.07
25010110
ADC_Shift_U
Indicates data configuration of U phase shift
Note:Factory parameters
N/A
d5.08
25010210
ADC_Shift_V
Indicates data configuration of V phase shift
Note:Factory parameters
N/A
d5.09
30000110
Voltage_200
ADC original data when DC bus voltage is 200 V
Note:Factory parameters
N/A