Kinco-KS series
26
Chapter 4 Software Introduction
4.1 Overview
Based on K5, KS use same Kincobuilder software and instructions. Users can reference
K5/K2 manual for most functions. The main difference is the new functions.
4.2 High speed counter
KS provides 4 high speed counters HSC0-HSC3.All can support up to 200KHz
High speed counter supports multiple modes: single phase, CW/CCW,AB phase (1
multiplication and 4 multiplication).
All high speed counter can support maximum 32 PV and support 32 “CV=PV” interrupts. PV
can be set as relative value or absolute value. If it is relative value,
4.2.1 Operation Modes and Inputs of the High-speed Counters
Input signals of high-speed counter include: clock (input impulse), direction, start and reset.
In different operation modes input signals is different. Please see below:
HSC 0
Mod
e
Description
I0.1
I0.0
I0.5
0
Single-phase up/down counter
with internal direction control:
SM37.3
Clock
1
Reset
2
Reset
Start
3
Single-phase up/down counter
with external direction control
Clock
Direction
4
Reset
Direction
6
Two-phase counter with up/down
clock inputs
Clock Down
Clock Up