the current and last sample data would be compared, if they are not the same, a new sample data
would be generated; otherwise, only the count for last state would be incremented and no new
sample data would be generated. And as a result of this, if the signal is discontinuous (for most
communication system) or change slowly, the sample depth would be extended greatly. However, if
the signal change rapidly the extension effect would not be so obvious. This is why the sample time
is less than expected when the sample depth is set above 100M (all the depth items with *) and the
signal changes rapidly.
5、 Auto update of the software fails
The software supports auto update, when a new version is released, a message would tell the
user to update. However, because of system permission and security policy of the operating system,
the auto update could fail. It this happens, the user could download the latest Kingst VIS software
from our website, and after uninstalling the software, the user could install the new version.
The download link of the latest Kingst VIS: http://www.qdkingst.com/en/download