Kingst Virtual Instruments User Guide
www.qdkingst.com
2016-8-20
the data will be sent to the computer at the same time. The PC software compresses and the data
and saves them in PC memories, and then it would restore the waveform and analyze it. As the data
needs to be sent to the computer and saved in real time, so the bandwidth is limited to the USB2.0
speed, that is, 480Mbps. As a result, when the device works with high sampling rate, only some of
the channels could be used. If you want to use all the channels, you have to reduce the sampling
rate. This series consists of LA1010 with with the highest sampling rate of 100M and LA1002, the
sampling rate of which is 24M.
3、 Technical specification
LAx016 Series:
Min detectable pulse width
Adjustable: -4~+4V
Min step: 0.01V
Adjustable: -4~+4V
Min step: 0.01V l
Adjustable: -4~+4V
Min step: 0.01V
UART/RS-232/485, I2C, SPI, CAN, DMX512, HDMI CEC,
I2S/PCM, JTAG, LIN, Manchester, Midi, Modbus, 1-Wire, UNI/O,
SDIO, SMBus, SWD, USB1.1, PS/2, NEC Infrared, Parallel, etc.
Windows XP、Vista、Windows 7/8/10(32bit/64bit)