PERIODIC SERVICE 10-15
DIRECTION FOR STORAGE
1. When shutting down the tractor for
long period of time, remove the bat-
tery from the tractor, adjust the elec-
trolyte to the proper level and store in
a dry place out of direct sunlight.
2. The battery self-discharges even
while it is stored. Recharge it once a
month in hot seasons and once every
two months in cold seasons.
IMPORTANT
The tractor has been shipped
with dry-type battery. Your dealer
will fill electrolyte and charge for
use for the first time.
CHARGING DRY TYPE BATTERY
1. Remove vent plugs and discard tem-
porary sealing cardboards and tapes.
2. Fill each cell with electrolyte having a
specific gravity given in Table 1 up to
highest level marked on the battery
case side.
sp. gr. of
Electrolyte
for Filling
sp. gr. of
Electrolyte
for fully
charged
TEMPERATE
Ordinarily
below
20°C (68°F)
1.260
1.260 ~
1.275
TROPICAL
Frequently
above 20°C
(68°F)
1.240
1.240 ~
1.255
AIR TEMPERATURES
3. After standing for 2 or 3 hours cor-
rect the electrolyte to former level.
4. Connect positive terminal (+) of
battery, with positive terminal of D.C.
charging unit, and negative terminal (-)
with negative terminal.
5. Batteries are preferably charged by
current showed in Table 2. Keep vent
plugs removed during charging.
< Table 2 >
TYPE
Volt (V)
Number of
plate per
cell
Capacity
at
20H.R
(A.H.)
Volume of
Electrolyte
(
)
Normal
Charging
Rate(A)
N70ZL 75D26L
PT80 -
34FR
12
15
70
4.7
7
12
13
65
4.2
7
12
-
100
5.4
5 ~ 10
< Table 1 >