EasyManua.ls Logo

Kioti DK55 - Changing Dry Type Battery; Direction for Storage

Kioti DK55
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PERIODIC SERVICE 10-15
DIRECTION FOR STORAGE
1. When shutting down the tractor for
long period of time, remove the bat-
tery from the tractor, adjust the elec-
trolyte to the proper level and store in
a dry place out of direct sunlight.
2. The battery self-discharges even
while it is stored. Recharge it once a
month in hot seasons and once every
two months in cold seasons.
IMPORTANT
The tractor has been shipped
with dry-type battery. Your dealer
will fill electrolyte and charge for
use for the first time.
CHARGING DRY TYPE BATTERY
1. Remove vent plugs and discard tem-
porary sealing cardboards and tapes.
2. Fill each cell with electrolyte having a
specific gravity given in Table 1 up to
highest level marked on the battery
case side.
sp. gr. of
Electrolyte
for Filling
sp. gr. of
Electrolyte
for fully
charged
TEMPERATE
Ordinarily
below
20°C (68°F)
1.260
1.260 ~
1.275
TROPICAL
Frequently
above 20°C
(68°F)
1.240
1.240 ~
1.255
AIR TEMPERATURES
3. After standing for 2 or 3 hours cor-
rect the electrolyte to former level.
4. Connect positive terminal (+) of
battery, with positive terminal of D.C.
charging unit, and negative terminal (-)
with negative terminal.
5. Batteries are preferably charged by
current showed in Table 2. Keep vent
plugs removed during charging.
< Table 2 >
TYPE
Volt (V)
Number of
plate per
cell
Capacity
at
20H.R
(A.H.)
Volume of
Electrolyte
(
)
Normal
Charging
Rate(A)
N70ZL 75D26L
PT80 -
34FR
12
15
70
4.7
7
12
13
65
4.2
7
12
-
100
5.4
5 ~ 10
< Table 1 >