EasyManuals Logo

Kipor IG2000 Shop Manual

Kipor IG2000
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
25
4. MAINTENANCE
4.1 Maintenance schedule
Regular service period(1)
Each use
First
month or
20 Hrs.
Every 3
months or
50Hrs.
Every 6
months or
100 Hrs.
Every
year or
300 Hrs.
Item perform at every indicated
month or operating hour interval,
whichever comes first
Engine Oil
Check
Replace
Air filter
Check
Clean ●②
Spark plug Clean-Adjust
Spark catcher Clean-Adjust
Valve clearance Check-Adjust ●③
Fuel tank and filter Clean ●③
Fuel line Check Every 2 year (Replace if necessary)
Note:
(1) For commercial use, operation hours are determined by proper maintenance.
(2) Service more frequently when operating in dusty areas.
(3) Service by an authorized Kipor service center.
Checking the oil level
Stop the engine and check the oil level, be sure to put the engine on a flat floor when checking.
1. Loosen the screws of the maintenance cover and remove the cover.
2. Remove the oil filler cap and check for the oil level.
3. If the oil level is low, add to the edge of the oil fill port.
© 2011 Kipor Power Systems, Inc.

Table of Contents

Other manuals for Kipor IG2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kipor IG2000 and is the answer not in the manual?

Kipor IG2000 Specifications

General IconGeneral
Rated Power1.6 kW
Voltage230 V
Frequency50 Hz
Fuel TypeGasoline
Starting SystemRecoil
Weight22 kg
Engine Type4-stroke, OHV
Noise Level54-59 dB(A)
Continuous Operation Time4 h (at rated load)

Related product manuals