(4) Pull out rope thrum from starter outer shell hole completely, pass it through the handle and
make a knot, then turn the handle cover. Loosen the reel to untension the spring, taking care not
to allow the reel to pop out.
(5) Install the starter pawl and fix it with bolts.
棘爪
棘爪导板
背面涂敷润滑脂
磨擦弹
棘爪弹簧
紧固螺栓
涂敷螺纹止动剂
(6) Pull the starter for several times, and check the ratchet wheel returning.
Pawl spring
Friction spring
Pawl
Pawl plate
Fixed bolt