3-6
In the Holiday Mode the following occurs:
Temperature selections remain at the current
setting, but are not displayed.
The
Water Filter Indicator is not displayed,
but monitoring continues.
The alarms are disabled.
The ice maker is disabled.
The interior lights are disabled.
T
he temperature displays and all of the LEDs
will be off, except for the Holiday Mode and
Cooling On/Off LEDs. The Holiday Mode and
Cooling On/Off LEDs will illuminate regard-
less of the door position.
K
eypad operation is disabled, with the excep-
tion
of the Holiday Mode key, or the Power
On/Off key.
The Holiday Mode will be cancelled when the
following occurs:
Pressing
the Power On/Off, or Holiday Mode
keypads.
W
hen the Holiday Mode is cancelled, the
Holiday Mode LED turns off, and the control
reverts to the settings in use prior to activation.
All inactive devices are restored, and the Water
Filter Indicator is updated.
The
Adaptive Defrost Control function contin-
ues during the Holiday Mode, but the control
will defrost at a fixed 12-hour interval.
OVER TEMPERATURE ALARM
The Over Temperature Alarm sounds, and the
indicator light flashes when either the refrigera-
tor
temperature exceeds 48°F (9°C), or the
freezer
temperature exceeds 15°F (–9°C) for
over
1-1/2 hours. The appropriate temperature
display flashes to show the user which com-
partment
is effected. The alarm stops if the
temperature(s) returns to normal, but the red
Over Temperature LED will continue to flash
(refer to “Master Alarm Reset” to reset the Over
Temperature Alarm).
MASTER ALARM RESET
Pressing the Over Temperature Reset will turn
off the audio alarm, but does not affect the indi-
cator
light the first time the Over Temperature
Reset is pressed. The indicator light will turn off
once the Over Temperature Reset is pressed
a second time. The audio alarm will not sound
again for the current condition that caused the
alarm until a new condition occurs.
A
Master Alarm Reset can be performed by
turning the power to the refrigerator off and
on again. The indicator light will turn on again
after the Over Temperature Reset is pressed,
if the condition that caused the alarm is still
present.
CALL SERVICE ALARM
Call Service is a visual and audio signal that
alerts the user that the refrigerator needs
service. The Call Service Alarm will sound
when:
Either thermistor has failed.
An
over-temperature condition occurs for
3 hours or more.
Reset using Master Alarm Reset.
Communication is lost with either the low
voltage Phoenix or main electronic control
board.
DOOR OPEN ALARM
If any door is left open for more than 10 min-
utes, the interior lights will be disabled, the
Door Open icon will flash, and the alarm will
sound. If the door is closed during the alarm
operation, the alarm will reset.
SALES DEMONSTRATION MODE
This mode provides a sequential display of
the temperature displays and feature LEDs.
To enter the Demonstration Mode, press and
hold the Max Cool and Power On/Off keys for
2 seconds. If the refrigerator or freezer door
is open for 10 minutes, the interior lights will
turn off.