6-3
SERVICE INFORMATION
The compressor suction and process stubs
can not be interchanged.
Refrigerant charge must be applied to the
high side only.
NOTE: The ice maker cycle must be
initiated electrically. Do not try to manually
start the cycle.
Service defrost bimetals open at 50°F
.
The defrost timer may contain a capacitor
in series with the motor. Do not test for
continuity when checking for a failed timer
motor. Instead, energize the timer, and
listen for gear movement.
The part number can be found on the
component.
IMPORTANT: Refrigerant must be handled
by a licensed, EPA-certified refrigerant
technician in accordance with established
procedures. Remove the refrigerant from
the existing system per the instructions
provided with the recovery system being
used.
•
•
•
•
•
•
•
SERVICEABLE ELECTRICAL PARTS MATRIX COMPONENTS
PERFORMANCE DATA
• (NORMAL OPERATING CONDITIONS)
AMB W
ATTS
SYSTEM PRESSURE
(PSIG)
HIGH SIDE LOW SIDE
70°
140±20 95±20 –7
TO 3
90°
150±20 135±20 –4
TO 3
110°
170±20 185±20 –2
TO 4
NOTE: Watt and pressure readings will vary,
and are influenced by the existing condition of
the appliance, such as an iced-up evaporator,
the condition of the condenser, the defrost
cycle, pull-down time, and customer use.
Normal operating conditions are viewed
when the air and temperature controls are
at mid-setting, the freezer section is at 0 to
5°F
, and the refrigerator is cycling.
•