7. Troubleshooting
7.2. Further possible faults
Error Cause Remedial action
The control unit will
not switch on.
No mains voltage. Check the FI switch and fuse in the power
supply.
LED on the humidity
sensor flashes,
cloud
symbol in the control
unit display flashes.
(SANARIUM M).
Lack of water. Fill evaporator M with water.
' See Chapter 5.10.
Steam does not exit
Cable failure. ' See Installation/Service Instructions Item
(S
N
RIUM M).
Heating rod defective.
no. 5080105
The cabin light is not
illuminated after
switching on.
Lamp defective. Change lamp.
1. Disconnect the control unit from the
mains.
2. Insert lamp with the same power rating.
The fan will not run.
No mains voltage. Check the FI switch and the fuse in the
power supply.
Output
1dead.
Fuse SI100 has triggered.
ReplacefuseSI100(1.25AT)orinformthe
Klafs Service.
Fan defective. Change fan.
1. Disconnect the control unit from the
mains.
2. Insert fan with the same power rating.
Continued on the next page