7. Troubleshooting
7.2. Further possible faults
Continued
Error Cause Remedial action
LED on the
evaporator lights up,
cloud
symbol in the
display of the control
unit flashes.
(SANARIUM S).
Lack of water. Open the angle valve on the evaporator.
' See Chapter 5.10.
Steam does not exit
(SANARIUM S).
The angle valve on the
evaporator is closed.
Open the angle valve on the evaporator.
' See Chapter 5.10.
The evaporator is not
switched on.
Switch on the evaporator.
' See Chapter 5.10.
Fault in the evaporator. ' See Chapter 8.3.
Fuse in the supply line has
triggered.
Inlet pump defective. Inform the Klafs service.
Yellow or red LED on
the evaporator
Evaporator servicing
required.
Service the evaporator.
' See Chapter 8.3.
shines
S
N
RIUM S
.
Steam cylinder is worn.
.
Inlet pump defective.
Inform the Klafs service.
Blow-off pump defective.
. Only for evapora-
tor S with
Birmingham
Scent container empty. Exchange the scent container.
' See ”Maintenance and Care” –
Chapter 8.4.
scenting:
Scent does not exit
Scent pump will not run or is
defective.
Inform Klafs service personnel.
(SANARIUM S).
Feed hose in the pump
defective.
' See service instructions article no.
5070175.
Scent line plugged or
defective.
Check scent line from the pump to the
evaporator pipe.
Exchange defective scent line.
Scent feed on the T-piece to
the evaporator pipe plugged.
Check scent line to the evaporator pipe.
Clean scent feed on the T-piece to the
evaporator pipe.
' See ”Maintenance and Care” –
Chapter 8.5.
Continued on the next page