7. FUNCTIONING PRINCIPLE
7.1 Ignition cycle
The ignition cycle can last max 18 minutes and is divided into three phases:
1 - FUN ASP : Intake device function
duration 8 seconds
2 - LOAD PELL : Pellet loading and resistance ignition
Pr01 = “LOAD PELL” duration
A pre-load phase may be present in “LOAD PELL” phase with specifications according to parameters Pr45,
Pr46 and Pr47.
3 - FIRE ON : Resistance switch-off and flame stabilising
Pr02 = “FIRE ON” duration
The stove goes to work phase at power set in ignition using buttons 1 and 2 after ignition cycle.