14. USEFUL ADVICE
Anticipate change to work phase without having to wait entire ignition cycle.
Keep key 5 pressed (power increase) to go directly to work phase without waiting for stove to perform the
entire ignition cycle. The flue gas must have reached minimum temperature to consider stove on (Pr13), to go
onto work phase. If not, stove repeats ignition cycle.
Do not perform following procedure during "Commissioning".
Anticipate a new stove ignition without having to wait stand-by time during switch-off phase.
Keep key 6 pressed (power decrease) to go directly to a new ignition without waiting for stove to perform the
entire ignition cycle.
The flue gas intake device is in this way switched off. Proceed with new stove ignition.
The stove goes to “At:te” state (wording appearing in lower display meaning “STAND-BY”) if the following
procedure is incorrectly performed in case of new ignition (see figure 13).
Display wood/pellet and water flue gas temperature.
The flue gas temperature on pellet and water side can be displayed during ignition or work phase by holding
key 1 down (temperature increase).
The flue gas temperature is displayed on upper display and water in stove temperature on lower display.
The flue gas temperature on wood side can be displayed during ignition or work phase by holding key 2 down
(temperature decrease).