7.2 Work phase
The set work power or 1, 2, 3, 4, 5, SANI (optional) is shown on upper display during the stove's normal
functioning.
A “SET H20 (maximum temperature) can be set by working from Power 1 to Power 5. The stove enters
Functioning Economy “ECO-H2O” upon reaching of such set.
Before reaching temperature set on “SET H20, the stove starts modulating power by decreasing pellet intake
and reducing flue gas intake device speed.
Example: “SET H2O” set at 75 °C
Work power set at 5
- The work power automatically changes to 4 upon reaching 71°C.
- The work power automatically changes to 3 upon reaching 72°C.
- The work power automatically changes to 2 upon reaching 73°C.
- The work power automatically changes to 1 upon reaching 74°C.
- The work power automatically changes to Functioning economy “ECO H2O” upon reaching 75°C.
The stove now automatically switches off if at least one of the following conditions exist:
If it remains in Functioning Economy “ECO-H2O for a time set on Pr23 (120 minute default setting).
If it exceeds temperature differential set on Pr12 (10°C default setting) or H2O Temperature > (SET
H2O” + Pr12)
With the following condition the stove automatically ignites:
If it drops below temperature differential set on Pr12 (10°C default setting) or H2O temperature < (“SET
H2O” Pr12)
If the above-mentioned condition occurs when the stove is still carrying out the switch off cycle, it is required to
wait until it ends.