3.2.4.1.1 RPM pickup
In this menu, the settings for the crankshaft signal, the type of ignition and the injection frequency
can be entered.
RPM Range:
By clicking on the function you can set the rpm range for the main parameter maps (minimum rpm
is 500 and maximum is 20.000).
Standard the 25 rows are divided over a rpm range 12.500 rpm (example see left figure below). If
your engine doesn’t make more than 6.500 rpm, you can devide the 25 rows over this 6.500 rpm
(example see right figure below). So the mapping will be more fine tuned for this engine rpm range.