EasyManua.ls Logo

KODERA CASTING C371A - Guideline to Select the Guide Pipe; MDU Board

KODERA CASTING C371A
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
14.Guideline to Select the Guide Pipe
AV
AVS
AVSS
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
0.3
0.5
0.85
1.25
2.0
3.0
1.8mm
2.2mm
2.4mm
2.7mm
3.1mm
3.8mm
2.5 φ
3 φ
3 φ
3.5 φ
3.5 φ
5 φ
0.5
0.85
1.25
2.0
3.0
2.0mm
2.2mm
2.5mm
2.9mm
3.6mm
2.5 φ
2.5 φ
3 φ
3.5 φ
4 φ
0.3
0.5
0.85
1.25
2.0
1.5mm
1.7mm
1.9mm
2.2mm
2.7mm
2 φ
2 φ
2.5 φ
2.5 φ
3.5 φ
CAVUS
KV,KHV,KVH
VSF,HVSF
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
0.3
0.5
0.85
1.1mm
1.3mm
1.5mm
1.5 φ
2 φ
2 φ
0.3
0.5
0.75
1.25
2.0
1.5mm
1.9mm
2.1mm
2.7mm
3.0mm
2 φ
2.5 φ
2.5 φ
3 φ
3.5 φ
0.5
0.75
1.25
2.0
2.5mm
2.7mm
3.1mm
3.4mm
3 φ
3 φ
3.5 φ
4 φ
UL1571
UL1015
UL1007
AWG
Final OD
Guide Pipe
AWG
Final OD
Guide Pipe
AWG
Final OD
Guide Pipe
28
26
24
22
0.88mm
0.98mm
1.11mm
1.30mm
1.5 φ
1.5 φ
1.5 φ
2 φ
28
26
24
22
20
18
16
2.00mm
2.10mm
2.23mm
2.38mm
2.57mm
2.83mm
3.15mm
2.5 φ
2.5 φ
2.5 φ
3 φ
3 φ
3.5 φ
3.5 φ
28
26
24
22
20
18
16
1.20mm
1.30mm
1.43mm
1.58mm
1.77mm
2.03mm
2.35mm
1.5 φ
1.5 φ
2 φ
2 φ
2 φ
2.5 φ
3 φ
CautionDepending on the manufacture or form of the wire, it may be appropriate to use a
thicker wire.
15. MDU Board
MDU board is controls each motor.
Turn the unit off when exchanging the MDU boards.
The voltage is on the unit for several minutes after the unit is turned off.
Wait at least five minutes before exchanging the MDU boards.
For right roller
For left roller
For cutter