4. Operation Panel
《Basic》 screen Standard Processing
When not selecting ⑤~⑨ on the 《Motion》 screen(P.11).
①《Front Strip Length》:Setting of the stripping length of the front
side insulation of the wire.(Input range 0.1~999)
②《Front Half Strip Length》:Setting of the half stripping length
of front side of the wire. (Input range 0.1~999)
③《Total Length》:Setting of the cutting length of the wire.
④《Rear Strip Length》:Setting of the stripping length of the rear side
Insulation of the wire. (Input range 0.1~999)
⑤《Rear Half Strip Length》:Setting of the half stripping length
of rear side of the wire. (Input range 0.1~999)
⑥《Core Diameter》: Depth of the blade when stripping the wire.
(See P,8) (Input range 0.01~10)
⑦《Blade Move Back》:Setting of the blade back when insulator is
stripped. (See P,9) (Input range 0.01~3)
⑧《Total Length Correction》:When “Set Total Length” and “Actually processed
total length of the wire” are different, correct it here.
0:No correction
For example)
⑨《-》:Minus key. When correcting the numerical value adversely at ⑧.
《-1》:Minus 1 key. The current number (quantity of wire to be processed) will
be reduced by -1.
⑩《Setting Pieces》:Setting of the pieces to be processed.