4.4
Section 4
Air Cleaner and Air Intake System
Air Intake/Cooling System
Clean Air Intake/Cooling Areas
To ensure proper cooling, make sure the grass screen,
cooling ns, and other external surfaces of the engine
are kept clean at all times.
Annually or every 100 hours of operation, (more oen
under extremely dusty, dirty conditions), remove the
blower housing and any other cooling shrouds. Clean
the cooling ns and external surfaces as necessary.
Make sure all parts are reinstalled. Torque the M6
blower housing fasteners to 7.7 N·m (68.3 in. lb.).
NOTE: Operating the engine with a blocked grass
screen, dirty or plugged cooling ns, and/or
cooling shrouds removed, will cause engine
damage due to overheating.