Remove Oil Sentry
Pressure Switch
(On Models So Equipped)
1. Disconnect the lead from the Oil Sentry™
pressure switch.
2. Remove the pressure switch from the center
passage or adapter elbow in the closure plate. See
Figure 8-2.
Remove Mufer
1. Remove the hex ange nuts or 5/16-18 capscrews
aaching the muer or exhaust system to the
engine. Remove any aached brackets. See Figure
8-4.
2. Remove the muer and gasket from the exhaust
port.
Figure 8-4. Removing Exhaust Flange Nuts (Stud
Design).
Remove Rectier-Regulator
1. Unplug the connector from the rectier-regulator.
2. Remove the two screws securing the rectier-
regulator to the crankcase. Remove the rectier-
regulator. See Figure 8-5.
Figure 8-3. Removing Blower Housing Screws.
Disconnect Spark Plug Lead
1. Carefully pull on the boot section and disconnect
the spark plug lead.
Figure 8-2. Removing Oil Sentry™ Switch.
Remove Blower Housing
1. Remove the four shoulder screws securing the
blower housing to the closure plate. See Figure
8-3.
2. Li the blower housing and separate the spark
plug lead from the corresponding slot.
Figure 8-5. Removing Rectier-Regulator.
Remove Electric Starter
1. Disconnect the starter lead from the terminal
stud.
2. Remove the two hex ange nuts securing the
starter to the closure plate. Remove the starter.
See Figure 8-6.